Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Diabetes Care ; 44(7): 1641-1646, 2021 07.
Article in English | MEDLINE | ID: covidwho-1346371

ABSTRACT

OBJECTIVE: Advances in continuous glucose monitoring (CGM) have transformed ambulatory diabetes management. Until recently, inpatient use of CGM has remained investigational, with limited data on its accuracy in the hospital setting. RESEARCH DESIGN AND METHODS: To analyze the accuracy of Dexcom G6, we compared retrospective matched-pair CGM and capillary point-of-care (POC) glucose data from three inpatient CGM studies (two interventional and one observational) in general medicine and surgery patients with diabetes treated with insulin. Analysis of accuracy metrics included mean absolute relative difference (MARD), median absolute relative difference (ARD), and proportion of CGM values within 15, 20, and 30% or 15, 20, and 30 mg/dL of POC reference values for blood glucose >100 mg/dL or ≤100 mg/dL, respectively (% 15/15, % 20/20, % 30/30). Clinical reliability was assessed with Clarke error grid (CEG) analyses. RESULTS: A total of 218 patients were included (96% with type 2 diabetes) with a mean age of 60.6 ± 12 years. The overall MARD (n = 4,067 matched glucose pairs) was 12.8%, and median ARD was 10.1% (interquartile range 4.6, 17.6]. The proportions of readings meeting % 15/15, % 20/20, and % 30/30 criteria were 68.7, 81.7, and 93.8%, respectively. CEG analysis showed 98.7% of all values in zones A and B. MARD and median ARD were higher in the case of hypoglycemia (<70 mg/dL) and severe anemia (hemoglobin <7 g/dL). CONCLUSIONS: Our results indicate that CGM technology is a reliable tool for hospital use and may help improve glucose monitoring in non-critically ill hospitalized patients with diabetes.


Subject(s)
Diabetes Mellitus, Type 1 , Diabetes Mellitus, Type 2 , Aged , Blood Glucose , Blood Glucose Self-Monitoring , Diabetes Mellitus, Type 2/drug therapy , Humans , Middle Aged , Reproducibility of Results , Retrospective Studies
3.
Diabetes Care ; 44(4): 1055-1058, 2021 04.
Article in English | MEDLINE | ID: covidwho-1076409

ABSTRACT

OBJECTIVE: The use of remote real-time continuous glucose monitoring (CGM) in the hospital has rapidly emerged to preserve personal protective equipment and reduce potential exposures during coronavirus disease 2019 (COVID-19). RESEARCH DESIGN AND METHODS: We linked a hybrid CGM and point-of-care (POC) glucose testing protocol to a computerized decision support system for continuous insulin infusion and integrated a validation system for sensor glucose values into the electronic health record. We report our proof-of-concept experience in a COVID-19 intensive care unit. RESULTS: All nine patients required mechanical ventilation and corticosteroids. During the protocol, 75.7% of sensor values were within 20% of the reference POC glucose with an associated average reduction in POC of 63%. Mean time in range (70-180 mg/dL) was 71.4 ± 13.9%. Sensor accuracy was impacted by mechanical interferences in four patients. CONCLUSIONS: A hybrid protocol integrating real-time CGM and POC is helpful for managing critically ill patients with COVID-19 requiring insulin infusion.


Subject(s)
Blood Glucose/analysis , COVID-19 Drug Treatment , COVID-19 , Critical Illness/therapy , Diabetes Complications , Insulin Infusion Systems , Insulin/administration & dosage , Remote Sensing Technology , Aged , Aged, 80 and over , Algorithms , Blood Glucose/metabolism , Blood Glucose Self-Monitoring/instrumentation , Blood Glucose Self-Monitoring/methods , COVID-19/blood , COVID-19/complications , Diabetes Complications/blood , Diabetes Complications/drug therapy , Equipment and Supplies , Female , Humans , Intensive Care Units , Male , Middle Aged , Point-of-Care Systems , Proof of Concept Study , Remote Sensing Technology/instrumentation , SARS-CoV-2
4.
Diabetes Care ; 44(3): 847-849, 2021 03.
Article in English | MEDLINE | ID: covidwho-1000011

ABSTRACT

OBJECTIVE: Real-time continuous glucose monitoring (rtCGM) in critically ill hospitalized patients holds promise; however, real-world data are needed. RESEARCH DESIGN AND METHODS: We placed Dexcom G6 CGM on intensive care unit (ICU) patients at Montefiore Medical Center with confirmed coronavirus disease 2019 (COVID-19) infection and glycemic variability. We analyzed inpatient CGM accuracy using point-of-care (POC) glucose-CGM matched pairs and included patients for analysis regardless of clinical status. RESULTS: We included 11 patients with CGM: 8 on continuous insulin infusion (CII), 8 on vasopressors, 8 intubated, 4 on high-dose glucocorticoids, 6 on renal replacement therapy, and 2 with anasarca. Accuracy was 12.58% for mean and 6.3% for median absolute relative difference. CGM reduced POC testing by ∼60% for patients on CII. CONCLUSIONS: In this real-world preliminary analysis of rtCGM during critical illness, we demonstrate early feasibility, considerable accuracy, and meaningful reduction in the frequency of POC glucose testing.


Subject(s)
Blood Glucose/analysis , COVID-19 , Intensive Care Units , Adult , Aged , Critical Care , Critical Illness/therapy , Female , Humans , Insulin/therapeutic use , Insulin Infusion Systems , Male , Middle Aged , Pandemics , Point-of-Care Systems , SARS-CoV-2
5.
Diabetes Care ; 44(2): 578-585, 2021 02.
Article in English | MEDLINE | ID: covidwho-979000

ABSTRACT

OBJECTIVE: Diabetes and hyperglycemia are important risk factors for poor outcomes in hospitalized patients with coronavirus disease 2019 (COVID-19). We hypothesized that achieving glycemic control soon after admission, in both intensive care unit (ICU) and non-ICU settings, could affect outcomes in patients with COVID-19. RESEARCH DESIGN AND METHODS: We analyzed pooled data from the Glytec national database including 1,544 patients with COVID-19 from 91 hospitals in 12 states. Patients were stratified according to achieved mean glucose category in mg/dL (≤7.77, 7.83-10, 10.1-13.88, and >13.88 mmol/L; ≤140, 141-180, 181-250, and >250 mg/dL) during days 2-3 in non-ICU patients or on day 2 in ICU patients. We conducted a survival analysis to determine the association between glucose category and hospital mortality. RESULTS: Overall, 18.1% (279/1,544) of patients died in the hospital. In non-ICU patients, severe hyperglycemia (blood glucose [BG] >13.88 mmol/L [250 mg/dL]) on days 2-3 was independently associated with high mortality (adjusted hazard ratio [HR] 7.17; 95% CI 2.62-19.62) compared with patients with BG <7.77 mmol/L (140 mg/dL). This relationship was not significant for admission glucose (HR 1.465; 95% CI 0.683-3.143). In patients admitted directly to the ICU, severe hyperglycemia on admission was associated with increased mortality (adjusted HR 3.14; 95% CI 1.44-6.88). This relationship was not significant on day 2 (HR 1.40; 95% CI 0.53-3.69). Hypoglycemia (BG <70 mg/dL) was also associated with increased mortality (odds ratio 2.2; 95% CI 1.35-3.60). CONCLUSIONS: Both hyperglycemia and hypoglycemia were associated with poor outcomes in patients with COVID-19. Admission glucose was a strong predictor of death among patients directly admitted to the ICU. Severe hyperglycemia after admission was a strong predictor of death among non-ICU patients.


Subject(s)
COVID-19/epidemiology , Diabetes Mellitus/epidemiology , Glycemic Control/statistics & numerical data , Hospitalization/statistics & numerical data , Adult , COVID-19/metabolism , Diabetes Mellitus/metabolism , Female , Hospital Mortality , Hospitals , Humans , Hyperglycemia/epidemiology , Hypoglycemia/epidemiology , Inpatients/statistics & numerical data , Intensive Care Units , Male , Middle Aged , Retrospective Studies , Risk Factors
SELECTION OF CITATIONS
SEARCH DETAIL